9.9 Object 6503h: Alarms
Additionally to the emergency message, object 6503h provides further alarm
messages. An alarm is set if a malfunction in the measuring system could lead to an
incorrect position value. If an alarm occurs, the according bit is set to logical high until
the alarm is cleared and the measuring system is able to provide an accurate position
value.
Unsigned16
Bit
Function
Bit = 0
Bit = 1
0
Position error
No
Yes
1
Reserved for further use
2
Reserved for further use
3
Reserved for further use
4
Reserved for further use
5
Reserved for further use
6
Reserved for further use
7
Reserved for further use
8
Reserved for further use
9
Reserved for further use
10
Reserved for further use
11
Reserved for further use
12
Manufacturer specific functions
13
Manufacturer specific functions
14
Manufacturer specific functions
15
Manufacturer specific functions
Position error
The bit is set, if no magnet is detected.