Description of CANopen-Interface
HYDAC ELECTRONIC GMBH
07.10.2010
Mat. No. 669824
Page 11 of 63
3 Technical data
Supply voltage:
................................12 / 24 V DC
Current consumption without load:
. < 100 mA
Measuring principle:
................................
magnetostrictive
Resolution:
......................................................
0.1 mm
Output data
Position – 32 Bit Integer
Speed – 16 Bit Integer
CANopen:
........................................................
EN 50325-4
Bus connection: ................................
ISO 11898-1, ISO 11898-2
CAN Specification 2.0 A:.............................
11-Bit Identifier
Communication-Profile:
CiA DS 301 V4.2
Device Profile ................................
CiA DS 406 V3.2
LSS:
CiA DS 305 V2.2
Node-ID: .....................................................
1…127
Baud rate: ...................................................
20, 50, 125, 250, 500, 800, 1000 kbit/s
Connection:
Copper cable 4 x 0.5 mm²
Special features:
................................Programming of the following parameters
via the CAN-BUS:
- Node adress
- Baudrate
- Code sequence
- Preset value
- PDO mapping
EMC:
................................................................
EN 61326/ISO 14982/ISO 7637/ISO 11452/EN 50121