Measured values
HMG 4000
Edition 2016-03-08 - V01 R04
[42]
Part No.: 669950
7.5.2 Evaluating CAN bus messages
This chapter is aimed at engineers, programmers, commissioning engineers
as well as service and maintenance staff with the corresponding knowledge
of automation technology, CAN bus systems in particular.
Before the HMG 4000 is set up in a running CAN bus system, corresponding
presets and parameter specifications need to be adjusted for the HMG 4000
according to the type and model of the CAN bus system and the way it is
connected.
If the HMG 4000 is connected to a running CAN bus system with incorrect
presets, this can lead to bus malfunctions, bus crashes and error functions
and as a result can also lead to damage to the machine, to the system and to
individuals.
In "
Evaluating messages
" mode, you
can access the main menu of this
CAN functionality, where you have
the option of adjusting the settings
according to your requirements. It is
more important that the following
settings be made first:
Baud rate
To evaluate the messages, the HMG
must be set to the baud rate of the
external bus system.
Baud rates of 10 kBit/s to 1 MBit/s
are possible.