Measured values
HMG 4000
Edition 2016-03-08 - V01 R04
[45]
Part No.: 669950
"General" message type
In this mode, you can
evaluate general
CAN messages.
For the message type "
General
"
the following listed parameter
settings are required.
Name
The entered name is used as the name of the measurement channel. If no name is
entered here, "
CAN channel x
" will be shown as the channel name.
Measurement range
Enter the lower and upper measurement range limit, unit and decimal format.
Resolution
Enter the value for the unit / bit.
Offset
Enter any offset there may be.
Frame type
Select the used frame type (standard / extended).
Message ID
Enter the message ID (hex) (0 - 1FFFFFFF).
Message format
Select the used message format (normal / multiplex).
With Multiplex, enter the
bit position and bit length of the selector
as well as the
value of the selector
.
Number display
Select the used number representation (whole number / floating point number).
Byte series
Select the byte order used (Little / Big Endian).
Bit position
Enter the corresponding bit position of the data (0 - 63).
Bit length
Enter the corresponding bit length of the data (1 - 64).