Recordings
HMG 4000
Edition 2016-03-08 - V01 R04
[63]
Part No.: 669950
Distribution of the measured values
After starting the event-controlled recording, the HMG 4000 will begin to record the
measured values for the set recording length. If the trigger event does not occur during
this time, the oldest measured values are replaced with new measured values in the
measured value memory. This means that you always have the set recording time as
the "past" in the measured value memory.
You can use the "
Distribution of measured values
" menu point to set how much of this
"History" should remain in the memory, when the event happens and how much into
the "future" you wish to record this event.
The 50/50 % setting, for example, means that with a recording length of 30
seconds, the 15 seconds before the event happens should be recorded, as should
the 15 seconds after it.
The 10/90% setting, for example, means that with a recording length of 30
seconds, the 3 seconds before the event happens should be recorded, as should
the 27 seconds after it.
After the end of a recording
Under this menu point you can set how you wish to proceed after the automatic ending
of the recording. Here you have the following options at your disposal:
Stop recording
The recording is stopped automatically and saves. No other recording starts
automatically.
Save and repeat without limit
The recording is stopped and saved, while at the same time another recording with
the same settings starts and is saved with a serial number. This operation repeats
until the recording is stopped manually.
Save and repeat with limit and repeat
The recording is stopped and saved, while at the same time another recording with
the same settings starts and is saved with a serial number. This operation repeats
for the specified number of repetitions or until the memory is full and is then
stopped automatically.