HYDAC FILTER SYSTEMS GMBH
Manual operation | 6
BeWa MFU-10P 4391553c en-us web
61 / 120
6.1 Switching the filter unit on or off/EMERGENCY-
STOP
Fig. 20:
Main switch
MFU-15E…
Fig. 21:
Main switch on
terminal box with DC
electric motor
1.
Switch the filter unit on at the main switch to operate it.
ð
The filter unit starts pumping.
2.
Switch the filter unit off at the main switch.
Operate the main switch in emergencies.
3.
If the main switch is switched off, pull the power plug out
or the battery clamps.
After switching the unit off at the main switch, depressurized
oil can escape at the ports depending on the conditions or
installation.
6.2 Observe the optical clogging indicator
Fig. 22:
Visual clogging
indicator
In order to utilize the absorption capacity of the filter element
optimally, a visual clogging indicator is located on the filter unit
. This visual clogging indicator displays the back pressure
upstream of the filter element during operation.
Check this clogging indicator daily during operation. Change
the filter element when there is a back pressure of 3 bar or as
soon as the clogging indicator enters the red zone.
1
2
3
4
5
6
7
8
9
A