HYDAC FILTER SYSTEMS GMBH
Performance and product description | 3
BeWa MFU-30E 4073898a en-us web
27 / 88
MFU-30E
– OUT
28L (M36x2, in accordance with
ISO8434-1)
Sealing material
Permissible fluid tempera-
ture range
-10 … 80°C
Permissible ambient tem-
perature range
-10 … 40 °C
2)
Permissible storage temper-
ature range
-10 … 40°C
Permitted air humidity dur-
ing storage
≤ 90% relative humidity, non-
condensing
Permitted air during storage Clean, dry, salt-free air, not near
oxidizing substances (rust film).
Protected from temperature fluc-
tuations and vibrations.
Storage duration:
Indefinite.
Before the unit is started up
again after being stored for more
than two years, replace all seals
and especially the hoses.
IP protection class accord-
ing to IEC 60529
IP54
3)
Connector cable, length
– AC electric motor
10 m including power plug
– DC electric motor
5 m including battery clamps
Emission sound pressure
level L
PA
≤ 70 db(A)
Design service life
If the service and maintenance
intervals are followed, the in-
tended service life of the unit is
not limited.
1)
@ 250 mm²/s when using original HYDAC accessories.
2)
At an installation height ≤ 1000 m above sea level.
1
2
3
4
5
6
7
8
9
A