5 | Setting up / assembly / integration of the filter unit
HYDAC FILTER SYSTEMS GMBH
50 / 88
BeWa MFU-30E 4073898a en-us web
5.7 Commissioning the filter unit
When you have checked the points listed here and can answer
them with OK, the filter unit is ready for operation.
1.
Insert a filter or empty element in the filter bowl.
NOTICE! Operation without a filter element or empty
element leads to leaks at the filter bowl.
2.
Check that the power supply cable is undamaged. Re-
place damaged cables immediately.
3.
Check that the suction and pressure hoses are undam-
aged. Replace damaged hoses immediately.
4.
Check the permissible ambient and fluid temperature
ranges, see
5.
Clean the protective screen, see
.
6.
Prior to each use, match the oil type in the filter unit to
the oil type to be pumped. If you are not sure which type
of oil is in the filter unit, or if you would like to pump a dif-
ferent type of oil than the previously pumped oil, empty
the filter unit completely and replace the filter element.
7.
Connect the filter unit to the power supply, see
.
8.
Connect the suction and pressure hoses or hang the
hoses in the container, see
9.
Switch the filter unit on and monitor the suction action
via the transparent suction hose. If the filter unit does
not pump any fluid after a max. of 5 minutes of opera-
tion, switch the filter unit off.
Fill the motor-pump group with fluid through the suction
hose and switch the filter unit on once again.
O
The commissioning is complete.
1
2
3
4
5
6
7
8
9
A