MRF7
Calculating the pressure differential of the filter housing / filter element
connection DIN DN 200
Differential pressure (bar)
Flow rate (l/min)
Filter element-
: pressure loss calculation, filter element
p
The following calculation is based on clean filter elements:
1000
)
(
min)
/
(
)
/
²
(
)
(
inch
L
n
l
Q
s
mm
V
R
bar
p
R
= R Factor
V = viscosity (mm²/s)
Q = flow rate (l/min)
N = Numbers of elements
L = Length of element (inch)
HYDAC FILTER SYSTEMS GMBH