8 | Performing Maintenance
HYDAC FILTER SYSTEMS GMBH
58 / 88
MoWa OLF-5Z OLF-10Z 4520794 en-us print
8.3 Change the filter element - DIMICRON
The procedure for changing the filter element
is
given in this chapter.
1x Allen wrench
= 5 mm
1x Allen wrench
= 6 mm
Proceed as follows for changing the
1.
The following activities refer to a filter unit / filter housing
with a pot.
ü
The hydraulic system / unit is switched off and the shut-
off devices are closed at the inlet section (IN) and the
outlet (OUT).
ü
The unit is secured from being inadvertently switched
back on.
2.
Provide a suitable container (1) to collect the escaping
operating medium.
Release pressure of the filter housing.
In addition, carefully open the drain plug (2) on the filter
bowl and drain the filter housing fully with the help of the
oil discharge cap (
= 6 mm) on the base of the filter
housing. The content is ≈ 2 liters.
Turn the drain plug after draining again in the filter bowl.