A | Appendix
HYDAC FILTER SYSTEMS GMBH
90 / 100
MoWa OLF-5 3433222d en-us web
Response pressure and indi-
cation range respectively
VM 2 C.x = 2 bar -10%
VM 3 C.x = 3 bar -10%
VM 5 C.x = 5 bar -10%
Permissible operating over-
pressure
≤ 210 bar
Permitted temperature range
-30 … +100°C
Connector threads
G ½
Installation space required
According to
Maximum tightening torque
33 Nm
Switching type
N/C or N/O
(change-over contacts)
Maximum switching voltage
230 V
Max. switching voltage at re-
sistive load
60 W
100 VA AC
Switching capacity
ohmic 3 A @ 24 V DC
ohmic 0.03 to 5 A @ 230 V AC
Electrical connection
Male connection M20
Female connector to
DIN EN 175301-803
Protection class in accordance
with DIN 40050
IP 65 (only if the connector is
wired and fitted correctly)
Tab. 14: Differential pressure indicator, electrical VM x C.x
1
2
3
4
5
6
7
8
A
Summary of Contents for OLF-10
Page 100: ...www hydac com ...