Unit setup/connection
Electrical connection of the unit
The unit has a connector cable with a power plug.
DANGER
Exposed electrical terminals in the terminal
box on the electric motor
Danger of fatal injury due to electric shock
Plug the power plug into a suitable, earthed, protected power outlet. Match
the specifications for the power supply and frequency on the unit with the
network specifications.
The filtration unit has a thermal motor protection switch to protect it from
electrical overload.
Checking the direction of rotation at the electric motor
Start the motor by switching it on for a short time (jog mode). The arrow on
the fan cover shows the correct direction of rotation.
If the rotation is in the opposite direction, reverse it by means of the phase
inverter in the connection plug.
OLSW
en(us)
Page 28 / 76
BeWa OLSW 4268435 en-us 2017-11-09.docx
2017-11-09
Summary of Contents for OLSW