Unit setup/connection
Connect the pilot line and monitoring line to the X2 and X3 terminal according
to the following description:
Terminal:
Pin
Function
Description
X3:1-2
Output
Device
ACTIVE
Potential-free relay contact. It is closed
when the motor pump assembly is
running.
X3:3-4
Output
Device OK Potential-free relay contact. This is
closed when there is no pending error.
Can be used, for example, to issue an
error notification when contact opens.
Opens, for example if the voltage
drops, the motor protection responds,
the filter is clogged, the collecting pan is
too full, etc.
X2:5-6
Output
Output
status
Potential-free relay contact.
1. If one of the two clogging indicators
reaches 75%, the outlet will flash (1
second on, 1 second off).
2. If one of the two clogging indicators
reaches 100%, the outlet will switch
on.
X3:7-8
Input
Input for potential-free push-button to
switch motor-pump group on/off. No
voltage is to be applied here.
Function:
To use the function, the unit at the main
switch needs to be switched on.
If the unit is ON and the potential-free
button is switched from open to closed,
the unit will stop.
If the unit is OFF, the main switch is ON
and the potential-free button is switched
from open to closed, the unit will start
up.
X3:9-10 Input
Collecting
tank
accessories
Collecting tank full.
OLSW
en(us)
Page 30 / 76
BeWa OLSW 4268435 en-us 2017-11-09.docx
2017-11-09