Remote control / Interval control Prioritization
After switching on the unit, the set interval and the switch-on time will be
started.
The motor-pump group can be switched on/off using the remote control. The
timer with the interval and the switch-on time will continue to run in the
background (remote control has priority).
If the motor-pump group is switched off via the remote control, it starts
automatically once the interval is over and runs time controlled via the timer.
If the motor-pump group is switched on via the remote control, it stops once
the interval is over. The timer has priority when switching off.
Thus, the set interval and the switch-on time are not influenced by the remote
control. Instead the timer assumes control again once the interval is over.
During activation of the manual drain, the unit cannot be operated via remote
control.
When the unit is switched on and the interval control is set to
, you
can control the unit using the remote start/stop function.
If the unit is switched off at the main switch, no remote-start function is
possible.
If the unit is switched on at the main switch, it can be started with remote-
start and stopped.
If the unit was stopped via remote maintenance, then you can start it again
by switching the main switch off and on.