Status LED / Causes and remedies
Status LED
Cause(s)
Remedy
LED is dark =
LED is off
The main switch is
off.
The main switch is
switched on and
the unit has an
error.
Restart protection
is active.
Switch on the main switch.
Note the other status LEDs.
Switch off the unit at the main
switch for 3 seconds and then
back on.
LED continuous
yellow light
The clogging
indicator whose
LED illuminates in
white has a defect
at 75% clogged.
Fix the error at the clogging
indicator whose LED illuminates
in white or replace the clogging
indicator.
LED continuous
green light
The main switch is
on and the unit is
running or can be
stopped via remote
stop or timer-
controlled. Also see
LED
flashing green.
No remedy is required.
LED continuous
yellow light
The drip tray
sensor reports fluid
in the drip tray.
Empty the drip tray, search for
the leakage and remedy it.
LED continuous
white light
The collecting tank
is full.
Empty the collecting tank.
LED flashing
white/yellow
The collecting tank
is full and the drip
tray sensor reports
fluid in the drip tray.
Empty the collecting tank.
Empty the drip tray, search for
the leakage and remedy it.