Status LED / Causes and remedies
Remedy error / cause at the fluid filter WBF
The following errors relating to the filter housing may occur during installation
or operation.
Malfunction
Cause
Remedying malfunctions
No flow
The shut-off devices at
the inlet/outlet are
closed.
Open the shut-off
devices slowly.
The filter element/filter
bag is blocked.
The back pressure or
differential pressure is
far too high.
Change the filter
element/bag/cartridge.
The filter housing cover
will not close.
The guide plate is still
installed when using
filter cartridges or a bar
magnet.
Remove the guide plate.
Leak between filter
housing and filter
housing cover.
The O-rings are
damaged.
Replace the O-rings.
(seal kit, see page 62)
The filter housing cover
is not tightened
properly.
Tighten the 4 nuts on the
filter housing cover.
No filtration
The seal ring on the
filter basket is damaged
or has not been
installed.
Replace the seal ring.
(seal kit, see page 62)
There is no filter
element installed in the
filter.
Insert the filter
element/bag/cartridge.