Performing maintenance
Check breather functionality
NOTICE
Breather not working
The filter area of the filter elements is not being used to its full potential.
►
Check the functionality of the breather at least once a week.
Check the functionality of the breather once a week.
1. The function test can only be carried out when the filtration unit is
running.
2. The air bleed plug has ventilation slots. Loosen the air bleed screw
approx. 2 thread turns.
- If fluid exits, the breather is working -> everything is OK.
- If air escapes, the function of the breather is disrupted -> Perform the
works detailed in chapter "Cleaning breather / Replacing parts" on page
3. Screw in the air bleed screw (134) and tighten it.
4. The function test is complete.