Performing maintenance
Changing the coalescing elements
At a differential pressure of 0.8 bar on the coalescing tank, the coalescing
elements must be replaced. The signal lamp
indicates that the
differential pressure has been reached.
1. Then switch off the unit at the main
switch.
2. Close the ball cocks at INLET WATER
and OUTLET WATER connections.
3. Drain the existing oil from the coalescing
container by manually letting it out
via the DRAIN OIL (4) port
connection into a suitable container.
4. Release the quick-action coupling (2) of
the breather by pulling back the ring (1)
and hang the supply line to the side.