Performing maintenance
5. Release the electrical connection to the
phase boundary sensor by rotating
counter-clockwise (1) and then pull apart
(2).
6. First release the upper tensioning clamp
= 13 mm counterclockwise and take
it off.
Then release the lower tensioning clamp
= 13 mm counterclockwise and take
the middle container part up and off.
7. Unscrew the three star grips (10.5) and
remove the element holding plate (10.4)
by lifting them upward.
Remove the coalescing elements and
dispose of them in an environmentally
friendly way.
Insert the new coalescing elements
(10.1) into the housing.
Do not use a hammer, etc.
Position the element holding plate (10.4)
and use it to center the coalescing
elements.
Screw on the three star grips (10.5) and
tighten them.
OLSW
en(us)
Page 59 / 76
BeWa OLSW 4268435 en-us 2017-11-09.docx