Preparing installation/preparing tank
OXiStop OXS-LID
en
Page 36 / 112
MoWa OXS-LID 3992764e en-us 2018-08-10.docx
2018-08-10
Installing the fluid level display (optional/accessory)
We recommend that you install a visual fluid level display on the tank.
Use the air-tight welded sleeves for fastening the fluid level indicator. Ensure
that bottom connector (7.241) of fluid level indicator (7.24) is mounted below
the diaphragm cage. Affix the upper connector (7.25) in the air-tight welded
sleeve.
Connect the top screw connection (7.25) directly to connection B15 on valve
block (4.1).
Ensure that top connector (7.25) is not connected to the
insides of the tank. Use a special connector to the fluid level
display for this purpose. See chapter "Accessories", on page
98.
Item
Designation
1
Diaphragm cage on the OXS-LID primary body
4.1
Valve and connection block
5.93
Fluid level/temperature sensor HNS, electric
6.1
Diaphragm
7.24
Filling level display, visual
7,241 Connector, open
7.25
Connector, closed
S
Safety buffer
X
Diaphragm/float swing path
Xn
Level of the diaphragm underside