Maintenance
OXiStop OXS-LID/-C202
en-US
Page 50 / 96
MoWa OXS-LID-C202 4461688 en-us 2019-07-08.docx
2019-07-08
Maintenance intervals
The inspection and maintenance work listed here is a necessary condition for
ensuring both long service life and error-free operation of the unit.
S
ee pag
e
24 h
our
s
/
d
a
ily
500 hour
s
/
m
ont
hl
y
300
0 ho
ur
s
/
ev
er
y
s
ix
m
ont
hs
600
0 ho
ur
s
/
ann
ual
ly
Unit
Check the unit for leaks (visual
check).
-
X
Check the screwed fittings to
ensure that they are secure
-
x
Check the pressure sensor on the
degassing unit and the fill level and
temperature sensors
-
X
Replacing the breather filter
X
Cleaning/replacing suction strainer
X
Diaphragm
Checking the diaphragm (visual
check)
-
X
Replacing the diaphragm
For the life cycle, see chapter
"Technical Data" on page 25.
After five years replace all the unit's hoses.
To carry out inspection and maintenance work on the OLF 5
bypass flow filtration unit, refer to the documentation applicable
to the product.