Filling the hydraulic tank with oil (first filling/oil change)
This chapter describes how to fill the hydraulic tank for commissioning / oil
change or maintenance via the OLF 5 bypass flow filtration unit (2.1).
Filling through the OLF 5 bypass flow filtration unit (2.1) ensures that the
hydraulic oil is always filled with clean, filtered oil.
As an alternative, fill the hydraulic tank with an external filling pump through
the port (B.08) or through a suitable port on the tank. Ensure that only clean,
filtered oil is filled in, during which the selector valve (4.7) is to be found at
position (a) and the screw plug (B22) is screwed out in accordance with the
instruction contained in Step 1. Then follow the procedures beginning with
Step 7.
NOTICE
Filling the unit via the breather filter
The unit/the breather filter will be damaged
►
Do not fill the unit via the breather filter (6.4).