Performing maintenance
VMU 1 ATEX II 2G IIC T4
en(us)
Page 49 / 60
BEWA VMU _4_ATEX-II2GIICT4_4066057 en-us 2015-10-12.doc
2015-10-12
Cleaning the suction screen in the lance
NOTICE
Operation without a suction strainer
The unit will be destroyed
►
Never operate the unit without a suction screen.
►
Clean the suction strainer regularly.
To protect the pump from coarse contamination or foreign bodies, a suction
screen is installed in the suction lance. Clean the suction strainer at regular
maintenance intervals.
Check/Clean the suction strainer immediately in the event of insufficient
suction or delivery action.
Clean the suction strainer by washing it out or by blowing it out with
compressed air.
1
2
3
4
5
6
Item
Description
1
Hose
2
Suction lance
3
O-ring
4
Suction strainer
5
Protection pipe
6
Suction screen set