HCF
Inst Issue 5: 18.06.15
Installation and Maintenance Instructions.
THESE INSTRUCTIONS MUST BE READ FULLY BEFORE COMMENCING INSTALLATION.
Owner / installer:
The life of this apparatus and its efficiency will be increased if
its use and maintenance is carried out in accordance with these instructions and
current statutory requirements. The installation and initial adjustments should be
carried out by a qualified and competent technician. Hydor Limited should be
consulted before substituting or fitting parts from another manufacturer. It is the
responsibility of the installer to verify that the installation is in accordance with
the following standards and the owner is given the current User’s Manual.
Any modifications to the fan or its installation, even the smallest
modification, change or elimination of security components or pieces that
influence the efficiency or loss of ventilation, will result in the CE Certification
and Hydor’s warranty being cancelled.
All sizes are supplied with 2 downrod lengths 400mm downrod fitted giving
610mm overall drop (from ceiling to base of motor body) 150mm downrod
supplied loose giving 360mm overall drop (from ceiling to base of motor body).
1. General
1.1 The fan must be sited and connected in accordance with current IEE
regulations (UK) or the appropriate standards in your country.
1.2 This appliance must be earthed.
1.3 The appliance is not intended for use by young children or infirm persons
without supervision.
1.4 Young children should be supervised to ensure that they do not play with
the appliance.
1.5 Check that the voltage and frequency on both the fan motor and
controller (if fitted) rating labels correspond with your electrical supply.
1.6 The installation must be provided with a double pole isolator switch
having a contact separation of not less than 3mm and protected with a
5 Amp fuse (UK).
1.7 Ensure that the safety wire is connected to the J-hook bracket before
operating the fan.
HCF
Ceiling Fan
incorrect
correct, minimum height 5mm