Titan 575 Owner’s Guide: 26
OPERATIONAL MAINTENANCE
Daily Maintenance
•
Check the engine oil level. Add oil if needed.
•
Check the high pressure pump oil. Add oil if needed.
•
Check the oil level in the blower. Add oil if needed.
•
Check coolant overflow bottle level. Add coolant if needed.
•
Inspect and clean the recovery tank filters.
• Inspect and clean the garden hose screen.
•
Inspect the truckmount for water and oil leaks, loose electrical connections, etc. and
repair as needed.
•
Lubricate the blower with a HydraMaster-recommended lubricant.
Weekly Maintenance
•
Inspect the recovery tank filters for tears, holes, etc. Repair or replace as needed.
•
Inspect the sacrificial anode assembly in the tank and repair or replace as needed.
• Inspect the vacuum relief valve. Clean and lubricate as necessary.
•
Clean the recovery tank thoroughly with pressure washer.
•
Check the pump belt, blower belt drives, and fan belt for wear and proper tension.
Adjust as needed.
•
Check all the hoses and wiring for wear and chafing. Secure as needed.
• Flush the water and chemical systems with solution of equal parts white vinegar and
water.
•
Check all the nuts and bolts. Tighten as needed.
• One time change of the high pressure pump oil after 50 hours of operation. (Every 500
hours thereafter.)
•
One time change of the engine oil and oil filter after 25 hours
of operation.
• Change the engine oil every 100 hours. (Every 50 hours if operating in high ambient
temperatures.) Change oil filter every oil change.
Monthly Maintenance
•
Check the engine air filter. Clean or replace as necessary.
•
Check the water level in battery. Fill as needed.
•
Check engine fan belt.
• Clean the battery terminals as needed.
•
Change the blower oil after first 100 hours of use.
Summary of Contents for Titan 575