background image

Wide Bottom:

 prevents the sprayer from tipping over

Translucent Bottle:

 make it easy to see the level of chemical

2 1/2 Gallon Bottle:

 the sprayer holds more chemical, allowing less 

frequent refilling.

Removable Bottle:

 allows for quick chemical switching

Large cap:

 enables easy refills and less chance of spills

15 Feet of Coiled Hose:

 Prespray upholstery with sprayer in one 

position

Built In Extension Holder:

 Keep out of the way on truck

Large Wheels:

 Easy movement on commercial jobs or large rooms

Extendable Handle: 

for easy transportation and movement 

Extra Jets Easily Attached:

 move from carpet prespray to upholstery 

prespray to protector with different jets

Easy Priming and Rinsing of Lines:

 removable jets

Easy to Fix: 

remove 6 screws to service pump or battery

Sealed Cavity:

 pump protected from spills

Flojet Water Pump:

 durable, easy to maintain, self-priming

Rotomolded Plastic:

 proven to last for years

Features and Benefits

Hose

Length: 15’

Diameter: 3/8” OD / 1/4” ID

Power Cord detachable

Length: 8 feet

Gauge: 16

Fuse

Amps: 10

Specifications

Pump

Flow: 1 gallon/minute

Pressure: 50 psi

Voltage: 115/102 volt AC

Amperage: 0.6 amp

Jets

Pre-spray:

Veejet, Hydro-Force 

part # B281, size = 8005

Protectant:

Teejet, Hydro-Force 

part # B006, size = 6501

Troubleshooting

Pump not turning 

on - No power

Not spraying 

properly

Solution dripping 

from jet with 

valve closed

Problem Cause 

Solution

No power from outlet

Fuse blown

Cord faulty

Faulty switches or internal wiring

Pump motor faulty

Pump seized

Reset breaker or move cord to 

another outlet

Check fuse - replace as needed

Replace cord

Check wiring & test switches - repair 

as needed

Replace pump motor

Repair or replace pump head & 

bearing - Check motor

Jet clogged

Jet worn

Chemical hose not submerged 

in jug

Chemcial filter clogged (intake)

Air leak in chemical hose (intake)

Chemical hose restricted (intake)

Chemical jug not vented

Spray hose restricted (outlet)

Spray valve faulty

Debris in pump head

Pump faulty

Faulty switches or internal wiring

Chemcial to thick to pump 

properly

Clean or replace jet

Replace jet

Make sure end of chemical hose 

with filter is in the chemical

Clean or replace filter

Repair or replace hose

Un-kink, clean out or replace hose

Remove cap - enlarge hole in cap 

for hose

Un-kink, clean out or replace hose

Repair or replace valve

Clean out pump head - Replace 

valves as needed

Repair or replace pump

Check wiring & test switches

Charge chemicals - Must be similar 

in viscosity to water

Spray valve faulty

Check valve faulty

Jet worn

Extension faulty

Repair or replace valve

Replace check valve

Replace jet

Replace extension

3

14

Summary of Contents for FlexiPro AS76

Page 1: ...ance unauthorized modification chemical incompatibility misuse abuse or exposure to freezing temperature conditions It does not cover normal wear items such as o rings valve seals pump seals hoses jets cords chemical bottles or other items which require replacement as a result of ordinary usage To obtain warranty service for the Flexi Pro Sprayer contact your distributor or Hydro Force If the spra...

Page 2: ...Diagram 4 Complete Sprayer Parts List 5 Sprayer Body and Gun Diagram 6 Sprayer Body and Gun Parts List 7 Sprayer Base Diagram 8 Sprayer Base Parts List 9 Wiring Flexi Pro AS75 10 Safety and General Maintenance 11 Operation 13 Troubleshooting 14 Warranty Information 16 Notes 15 ...

Page 3: ...ectant Teejet Hydro Force part B006 size 6501 Troubleshooting Pump not turning on No power Not spraying properly Solution dripping from jet with valve closed Problem Cause Solution No power from outlet Fuse blown Cord faulty Faulty switches or internal wiring Pump motor faulty Pump seized Reset breaker or move cord to another outlet Check fuse replace as needed Replace cord Check wiring test switc...

Page 4: ...Move the sprayer to the location where the sprayer is to be used 7 Turn the switch to the ON position and spray chemical as needed When the job is completed turn the switch to the OFF position 8 Remove the chemical feed hose from the chemical container and replace the solid cap for storage 9 Place the chemical feed hose into a container filled with water 10 Turn the switch to the ON position and s...

Page 5: ... NM4117 Rubber Bushing 3 4 2 NM4064 Washer Spacer 4 NS174 Fuse 1 NS177 Fuse Casing 1 BR060 Splicer 1 4 Barbs 1 Complete List of Parts Run fresh water through the sprayer after each day of use to flush chemical from the pump and hoses Keep chemical containers and strainer screen clean While sprayer and pump are made with chemical resistant materials and can handle a wide range of chemicals do not a...

Page 6: ... plug This sprayer is for use on a nominal 120 volt circuit and has a grounding plug that resembles the plug illustrated in the sketch below Make sure that the power cord for this sprayer is connected to an outlet with the same configu ration as the plug No plug adapter should be used with this sprayer The power cord supplied with the AS76 FlexiPro sprayer is properly sized to handle the electrica...

Page 7: ...0817 Tubing 48 C NM4116 Rubber Bushings 3 8 2 D NM4110 Extendable Handle 1 E NM4061 Base Plate Screws 10 F NM4080 Handle Screws 2 G NM4105 Wheel 2 H XHA07 3 8 Aluminum Axle Rod 16 75 I NM4104 Axle Cap 2 J NM5020 Wire Red 2 feet K NM4064 Washer Spacer 4 L NM4113 Molded Plastic 1 M NA0840 Strainer 1 N NA0839 Barb Nylon 1 O NM4117 Rubber Bushing 3 4 2 P BR335 Quick Connect Male 1 Q NA0802 Strainer Bo...

Page 8: ...NS123 Hose Clamps 3 8 4 L NS162 Elbow Barbs 2 M AP21 Water Pump 1 N PA175 Wire Black 6 O NS126 Power Recepticle 1 NM4123 Screws Power Recepticle 2 NM4031 Nuts Power Recepticle 2 P NM4115 Pump Base Bolts 2 NS174 Fuse 1 amp not shown 1 Q NS177 Fuse Casing 1 R BR060 Splicer 1 4 Barbs 1 9 Sprayer Base Diagram Back of Sprayer 8 A E R D F C B Q A D F P H N N G I A L M L K A J K Connect draw tube NA0817 ...