9
Operation Procedures
Knowledge of the proper operation of the MX200 is required to ensure
user safety and efficient performance of the extractor.
SET UP AND OPERATION
1. Electrical Cords:
One 25’ power cord is supplied with the standard Nautilus MX200. This cord powers vacuum #1, vacuum
#2, the Solution Pump, and the cooling fan and the waste pump if so equipped.
A second cord is added if equipped with the optional 1750W heater. Cord#2 will power the heater and the
waste pump if so equipped.
The amperage required by each cord requires that the two cords be plugged into separate circuits:
•
Cord #1 (Left side) Must be plugged into a 20amp circuit.
•
Cord #2 (Right side) Units with heater only, Cord #2 can be plugged into a 15amp circuit. Units with the
heater and the optional APO, it must also be plugged into a 20amp circuit when using both the heater &
waste pump.
20amp circuits are usually found in kitchens and bathrooms.
An overloaded circuit will not always trip
the circuit breaker immediately, but it may not provide sufficient voltage for proper operation and the breaker
may trip eventually.
On dual cord units, plug the two power cords into two outlets from different circuits. If the Dual Circuit
Indicator green light fails to light, you may be on the same circuit and may need to select a different plug for
one of the cords. If the Dual Circuit Indicator green light comes on, you are plugged into two different
circuits. Proceed with your set-up procedure.
(Dual Circuit Indicator light may take up to 30 seconds to recognize the two circuits and turn ON.)
If a circuit breaker trips or the pump circuit breaker trips during operation, reset the breakers and move the
cord to another outlet as needed.
When operating the MX200 with the optional 1750W heater
DO NOT turn the heater on until after the pump has been primed and solution hose
and tool connected – Steps #3, #4 & #5.
Power Cord – AX32
25’ – 12 gauge M-F Plugs
Cord #1
Dual Cord Set-up
Only with Optional 1750W Heater
Cord #2
Standard Single Cord Set-up
Dual Circuit Indicator
Summary of Contents for Nautilus MX200
Page 1: ...1 LMANN06 Revised 01 29 2015 Nautilus MX200 Operating Manual ...
Page 38: ...38 OPTIONAL AUTO FILL FLOAT VALVE ASSEMBLY NM5740 ...
Page 39: ...39 Optional Pump Out Pump AP37 PARTS ASSEMBLY ...
Page 40: ...40 1 2 5 6 7 8 9 11 3 8 9 12 4 4 3 10 8 9 9 8 2 39 ...
Page 49: ...49 OPTIONAL PUMP OUT PARTS 96 91 97 9 94 105 93 OPTIONAL PUMP OUT CONNECTIONS 99 95 111 111 ...