25
NAUTILUS MX3-200HE SWITCH PANEL:
(Shown with optional Pump-Out switch.)
Vacuum #2 – Power from Cord #2.
When the switch is turned to the ON position
power is supplied to the vacuum motor.
(3-Stage Vacuum)
Solution Pump Switch – Power from Cord #1
.
When the switch is turned to the ON position
power is supplied to the solution pump motor.
When not using solution (Extracting only) do not
turn this switch ON.
OPTIONAL - Waste Pump Switch
Power from Cord #2.
Do not turn Waste Pump
Switch ON unless a hose is connected to the
Pump-out Outlet port.
For pump protection there is a pressure switch
which will turn the waste pump off if the
pressure in the discharge line gets too high, as
it would if the pump was turned on while the
outlet cap was still in place.
Vacuum #1 – Power from Cord #1.
When the switch is turned to the ON
position power is supplied to the vacuum
motor. (3-Stage Vacuum)
Cooling Fan – Power from Cord #1.
The cooling fan is not controlled by any switch.
As soon as Cord #1 is plugged in the cooling
fan will turn on to exhaust air from the base.
Heater #1 –
Power from
Cord #1.
When the switch
is turned to the
ON position
power is supplied
to the first
1000W heating
element.
Heater #2 –
Power from
Cord #2.
When the switch
is turned to the
ON position
power is supplied
to the second
1000W heating
element.
Summary of Contents for Nautilus MX3-200HE
Page 1: ...1 LMANN09 Revised 02 16 2018 Nautilus MX3 200HE Operating Manual ...
Page 37: ...37 OPTIONAL AUTO FILL FLOAT VALVE ASSEMBLY NM5740 ...
Page 38: ...38 Optional Pump Out Pump AP37 PARTS ASSEMBLY ...
Page 39: ...39 1 2 6 7 8 9 11 3 8 9 12 4 4 3 10 5 15A 8 9 8 9 39 2 ...
Page 43: ...43 48 49 49 47 47 47A 47 47 47A 47A 51 51 37 9 54 64 52 VACUUM MOUNTS CONNECTIONS 9 54 64 ...
Page 48: ...48 96 91 97 9 94 105 OPTIONAL PUMP OUT CONNECTIONS 99 95 93 103 ...
Page 49: ...49 FLOW 81 92 91 99 96 97 105 13 14A 14 95 OPTIONAL PUMP OUT PARTS 1 9 97 103 39 9 ...
Page 50: ...50 HEATER PARTS 111 113 114 112 2 115 2 116 2 42 42A 98 111 ...