17
9. Pressure Adjustment:
To make it easier to check and adjust the pressure, the pressure gauge and the pressure regulator are mounted
on the control panel on the front of the machine. When the high-pressure solution pump is on and primed,
pressure will show on the gauge.
•
To decrease the pressure, turn the brass knob on the pressure regulator to the left (counter-
clockwise.)
•
To increase the pressure, turn the brass knob on the pressure regulator to the right (clockwise.)
•
To adjust pressure to your tool and surface requirements:
o
Check the pressure on the gauge.
o
Re-adjust as needed to set the machine at the desired pressure.
o
Choose the pressure setting that best meets your type of cleaning.
Pressure gauge & Regulator/Unloader
To increase the solution pressure, turn the
regulator knob clockwise.
To decrease the solution pressure, turn the
regulator knob counter-clockwise.
The maximum pressure setting is 500psi; however,
the highest pressure attained is dependent on the
amount of water flow at the tool:
•
Smaller jets and lower flow will allow for
higher pressure at the tool.
•
Larger jets and higher flow will lower the
maximum pressure attained at the tool.
The desired setting will depend on the type of
cleaning and tool used. For example:
•
Carpet Cleaning with 2-jet AW29 wand: 400psi
•
Upholstery Cleaning with AW50D tool: 200psi
If adjusting or maintaining pressure becomes a
problem, refer to the trouble shooting guide or
contact your distributor for advice or assistance.
Summary of Contents for Nautilus MX3-500HE
Page 1: ...1 LMANN18 REVISED 01 29 2015 MX3 500HE Nautilus Operating Manual ...
Page 39: ...39 OPTIONAL AUTO FILL FLOAT VALVE ASSEMBLY NM5740 ...
Page 40: ...40 Optional Pump Out Pump AP37F PARTS ASSEMBLY ...
Page 41: ...41 2 4 4 6 7 10 11 3 8 9 3 5 1 8 9 8 9 2 39 12 8 9 ...
Page 48: ...48 2 39 1 72 73 73 67 9 30 31 82 83 2 83 82 84 INSIDE SOLUTION TANK BOTTOM VIEW SOLUTION TANK ...
Page 50: ...50 96 91 97 9 88 111 94 105 93 OPTIONAL PUMP OUT CONNECTIONS 99 95 118 ...
Page 51: ...51 FLOW 81 92 91 99 96 9 97 105 13 14A 14 95 OPTIONAL PUMP OUT PARTS 1 39 97 9 118 ...
Page 52: ...52 HEATER PARTS 42 42A 98 114 110 71 113 114 ...