20
Problem
Cause
Solution
Dual Circuit
Cords on the same circuit
Move one cord to outlet on different circuit
Indicator
No voltage from one/ both outlets
Check circuit breakers – Reset breakers or move cords
Not Lighted
Light Bad
Replace Light
Dual Circuit Indicator Bad
Replace indicator
One/Both Outlets Wired wrong
If hot & neutral sides switched on outlet, machine will work,
but light will not turn ON.
Pump-out
Building circuit breaker tripped.
Reset breakers or move cords to other outlets
not working
Faulty power cord
Replace cord (
1696-6412
)
Faulty switches or internal wiring
Check wiring & test switches - Repair as needed *
(NM5714)
Pump-out pump faulty
Replace pump-out pump (AP37)
Pump-out float switch faulty
Replace Float Switch
Float Switch movement restricted
Clean debris off of Float Switch or adjust float
Discharge hose restricted
Un-kink, clean out or replace hose
Pump-out pump clogged
Remove and clean out pump
Vacuum
Building circuit breaker tripped.
Reset breakers or move cords to other outlets
Motor
Faulty power cord
Replace cord (
1696-6412
)
not running
Faulty switches or internal wiring
Check wiring & test switches - Repair as needed *
Vacuum motor faulty
Replace vacuum motor (AV14)
Loss of
Vacuum motor faulty
Replace vacuum motor (AV14)
Vacuum
Vacuum motor gasket damaged
Replace gasket (PA010)
Recovery tank lid gasket damaged Replace gasket (NM5718)
Drain valve open
Close valve
Drain valve leaking
Repair or replace drain valve (PEA11)
Vacuum motor hoses loose /
leaking
Reconnect or replace vacuum motor hoses
Vacuum Valve in wrong Position
Check Vacuum Gate Valve Position. – PAGE 8
Vacuums not connected properly
See vacuum connection instructions – PAGE 8
Vacuum hose or tool clogged
Clean out vacuum hoses and tool
Vacuum hoses or cuffs leaking
Replace vacuum hoses, cuffs & connectors as needed
Recovery tank full
Drain tank
Float shutoff filter clogged
Clean float shutoff filter
Float stuck in float shutoff
Repair or replace float shutoff
Pump-out Pump faulty
Repair or replace pump out pump (AP37)
Recovery tank damaged
Replace recovery tank
Chemical not
Solution tank not filling
Check & repair auto fill assembly
feeding
Chemical hose restricted
Un-kink, shorten, clean out or replace hose
Filter screen plugged
Clean or replace filter (PDE100-11P)
Low Incoming Water Pressure
Move bottle & shorten chemical hose to improve draw –
Find other water source.
Wrong size metering tip
Change metering tip
Chemical proportioner faulty
Replace chemical proportioner (PDE61-22-3)
Check valve in filter faulty
Replace filter (PDE100-11P)
*
To reduce the risk of fire electrical shock or injury repairs to wiring should only be performed by
experienced service technicians.
If you are not experienced in checking electrical wiring contact your nearest authorized service
center to perform tests and repairs to wiring and switches.
Summary of Contents for Nautilus MX3-500RP
Page 3: ...3 Aramsco ...
Page 4: ...4 ...
Page 5: ...5 1696 6412 10 1696 6412 10 ...
Page 6: ...6 ...
Page 7: ...7 o ...
Page 8: ...8 o o ...
Page 9: ...9 Power Cord 1696 6412 25 10 gauge M F Plugs Cord 1 Cord 2 Dual Circuit Indicator Light ...
Page 14: ...14 ...
Page 17: ...17 o o o o ...
Page 18: ...18 ...
Page 22: ...22 ...
Page 23: ...23 ...
Page 24: ...24 ...
Page 25: ...25 ...
Page 26: ...26 ...
Page 27: ...27 o o ...
Page 28: ...28 ...
Page 29: ...29 Pour 2 or 3 gallons of clean water into Solution Tank ...
Page 34: ...34 ...
Page 35: ...35 KIT A PT054 KIT B PT055 KIT C PT056 ...
Page 36: ...36 ...
Page 37: ...37 ...
Page 38: ...38 ...
Page 39: ...39 ...
Page 40: ...40 ...
Page 41: ...41 ...
Page 42: ...42 ...
Page 43: ...43 ...
Page 44: ...44 ...
Page 45: ...45 ...
Page 46: ...46 ...
Page 47: ...47 ...
Page 48: ...48 ...
Page 49: ...49 ...
Page 50: ...50 1650 5397 1663 3397 ...
Page 51: ...51 ...
Page 52: ...52 ...
Page 53: ...53 ...
Page 54: ...54 ...