310-0510 IHT
9
SECTION 4. SERVICE AND MAINTENANCE
NOTE: Any servicing dealer attempting
a warranty repair must have prior
approval before conducting maintenance
of a Hydro-Gear
®
product unless the
servicing dealer is a current Authorized
Hydro-Gear Service Center.
EXTERNAL MAINTENANCE
Regular external maintenance of the 310-0510
IHT should include the following:
1. Check the vehicle operator’s manual for
the recommended load ratings. Insure
the current application does not exceed
load rating.
2.
Check oil level in accordance with
Figure 4
Page 10.
3. Inspect the vehicle drive belt, idler pulley(s),
and idler spring(s). Insure that no belt
slippage can occur. Slippage can cause low
input speed to the transmission.
4. Inspect the transmission cooling fan for
broken or distorted blades and remove any
obstructions (grass clippings, leaves, dirt,
etc.).
5. Inspect the axle parking brake and vehicle
linkage to insure proper actuation and
adjustment of the parking brake.
6. Inspect the vehicle control linkage to the
directional control arm on transaxle. Also,
insure the control arm is securely fastened
to the trunnion arm of the transaxle.
7. Inspect the bypass mechanism on the
transaxle and vehicle linkage to insure it
actuates and releases fully.
SERVICE AND MAINTENANCE
PROCEDURES
All the service and maintenance procedures
presented on the following pages can be
performed while the 310-0510 is mounted on
the vehicle. Any repair procedures as
mentioned in the repair section of this manual
must be performed after the unit has been
removed from the vehicle.
FLUIDS
The fluids used in Hydro-Gear products have
been carefully selected, and only equivalent, or
better products should be substituted.
Typically, an engine oil with a minimum rating
of 9 cSt (55 SUS) at 230°F (110° C) and an API
classification of SL is recommended. A 20W-50
engine oil has been selected for use by the fac-
tory and is recommended for normal operating
temperatures.
FLUID VOLUME AND LEVEL
Fluid volume information is provided in Table 3.
Certain situations may require additional fluid to
be added or even replaced. Refer to Page 4
and Figure 4 for the proper fill port location.
Fill the 310-0510 to the top of the oil fill port.
Recheck the fluid level once the unit has been
operated for approximately 1 minute.
Purging may be required. Refer to the purging
procedures on page 11.
Summary of Contents for 310-0510
Page 7: ...310 0510 IHT 5 MODEL RECOGNITION 618 0319 166768 104 1760 173839 036932 618 0389A ...
Page 32: ...310 0510 IHT 30 310 0710 EXPLODED VIEW ...
Page 34: ...310 0510 IHT 32 310 0610 EXPLODED VIEW ...
Page 36: ...310 0510 IHT 34 310 0510 EXPLODED VIEW 6 SEALANT 57 20W 50 OIL 127 SEAL O RING KIT ...