135
9 - T
ਠਭਲਯਮਲ਼
, S
ਲ਼ਮਠਦਤ
ਠਭਣ
M
ਠਨਭਲ਼ਤਭਠਭਢਤ
Inspections and Maintenance
Annual Inspections and Maintenance
Recertifi cation of the Overspeed Safety Device
Annual inspections must be performed by a qualifi ed technician. For more
information about qualifi ed technicians, refer to p. 7 of the
Performance and
Safety Rules
section.
Each Hydro Mobile motorized unit must be submitted to an annual inspection performed
by a qualifi ed technician. This annual inspection must be carried out
no later than 13
months after the previous annual inspection
.
Maintenance and inspection logs must be kept on record for warranty and safety purposes.
Blank copies of the annual inspection checklist must be fi lled out when annual inspection
operations are carried out. The notes and comments form must be used to indicate any
discrepancy or any item found to be not acceptable. Any discrepancy must be reported
to the competent person and appropriate corrective action must be taken immediately.
Corrective actions must be performed by a qualifi ed technician. For more information
about qualifi ed technicians, refer to p. 7 of the
Performance and Safety Rules
section.
It is recommended to use replacement parts manufactured by or recommended by
Hydro Mobile. The use of substitute parts could not only void the warranty covering this
motorized unit and its components but cause serious damages that could lead to injury
or death. It is recommended to replenish and grease components only with fl uids and
lubricants recommended by Hydro Mobile.
The overspeed safety device is the main safety component on Hydro Mobile F2 Series
motorized units. Each overspeed safety device must be submitted to a factory rebuild and
recertifi cation no later than every 5 years.
The F2 Series overspeed safety device is a unit sealed by Hydro Mobile and must not
be opened, modifi ed or tampered with under any circumstances. If an overspeed safety
device shows signs of tampering or if the tamper-proof seals are missing, the overspeed
safety device must be factory recertifi ed.
The dismantling and installation of an overspeed safety device must only be performed
by a qualifi ed technician.
Drop tests of the motorized unit must be performed only by a qualifi ed technician.
For more information about qualifi ed technicians, refer to p. 7 of the
Performance and
Safety Rules
section.