35
Page
IF YOU SMELL GAS:
•
Do not try to start the micro-boiler.
•
Do not touch any electric switches; do not use any phone in your building.
•
Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s ins
tructions
.
•
If you cannot reach your gas supplier, call the
fi
re department.
WARNING
Opera
tion
1.
Once
the above checks have been completed, please clean
fil
ter of any debris. Refer to p. 44 for ins
tructions
.
2.
F
ully open the manual water control valve on the water
supply line.
3.
Turn on the thermostat and verify that fluid flows
through your radiant system. Then turn off your
thermostat.
4.
F
ully open the manual gas control valve installed.
5.
T
urn on the 120 VAC, 60 Hz power supply to the water
heater.
6.
Now turn on the thermostat. You are ready to enjoy hours
of endless comfort.
•
Check the GAS
and
WATER CONNECTIONS
for leaks before
firing
unit for the
fi
rst
time
.
•
Open the main gas supply valve to the micro-boiler using only your hand to avoid any
spark. Never use tools. If the knob will not turn by hand, do not try to force it; call a quali-
fied
service technician. Forced repair may result in a
fi
re or explosion due to gas leaks.
•
Be sure to check for the presence of leaking gas toward the bo
tt
om of the micro-boiler
because some gases are heavier than air and may se
ttle
towards the
floor
.
•
Check the GAS PRESSURE
. Refer to p. 24.
•
Do not try to light the burner manually. It is equipped with an electronic
ignition
device
which automa
ti
cally lights the burner.
•
Check f
or
PROPER VENTING
and
COMBUSTION AIR
to the micro-boiler.
•
Purge the GAS
and
WATER LINES
to remove any air pockets.
•
Do not use this micro-boiler if any part has been submersed under water. Immediately call
a quali
fied
service technician to inspect the micro-boiler and to replace any damaged parts.
FOR YOUR SAFETY, READ BEFORE OPERATING
INITIAL OPERATION