TROUBLESHOOTING
GENERAL
PROBLEM
SOLUTIONS
TEMPERA
TURE
and
AMOUNT
OF
HO
T
W
ATER
It takes a long
time
to
get hot water at the
emitters.
•
If you would
li
ke to r
ecei
ve hot water to your
fi
xtures
quic
ker, you
m
ay
want to c
onsi
der a hot water r
eci
rcula
tion
syst
em.
(p
.
27)
The water
is
not hot
enough
.
• Compa
re the
fl
ow and t
empe
rature
.
See the charts on p
.
50.
•
Check cross
plumbing
b
etween cold water
lines
and hot water
lines.
•
Is the gas supply valve fully open? (p
.
29)
•
Is the gas
line
si
zed properly? (p
.
21)
•
Is the gas supply pressure su
fficie
nt? (p
.
20 and 22)
•
Is the set t
empe
rature set too low? (p
.
34 to 36)
The water
is
too hot
. •
Is the set t
empe
rature set too
high?
(p
.
34 to 36)
The hot water
is
not
av
ailable
when a
there is a call for
heat.
•
Make sure the
unit
has 120 VAC, 60 Hz power supply
.
•
Is the t
empe
rature controller
power button turned on?
•
Is the gas supply valve fully open? (p
.
29)
•
Is the
system Y-strainer
clean?
• Can the emitters
su
fficie
ntly draw at least
0.5 GPM (1.9 L/min)
through the water heater?
(p. 34)
•
Is the
unit
frozen? (p
.
37)
•
Is there enough gas
in
the tank
/
cylinder?
(For Propane
model)
•
Is
it
plumbed
back
wards
with
reverse
plumbing?
The hot water turns
cold and stays cold
.
•
Is the
fl
ow rate enough to keep the
micro-boiler
running?
(p. 34)
•
Is the gas supply valve fully open? (p
.
29)
•
Is the
system Y-strainer
clean?
•
Is the
system
clean of
debris
and o
b
s
tructions?
Fluctua
tion
in
hot
water t
empe
rature
.
•
Is the gas
line
si
zed properly? (p
.
21)
•
Is the supply gas pressure su
fficie
nt? (p
.
20 and 22)
•
Check for cross c
onnection
b
etween cold water
lines
and hot water
lines.
Owner's Guide
Summary of Contents for HS120CON-LP