5
Page
Introduction
Installation
Manual
INTRODUCTION
•
This manual provides informa
tion
necessary for the installa
tion,
opera
tion,
and maintenance
of the micro-boiler.
•
The model descrip
tion
is listed on the ra
ting
plate which is a
tt
ached to the side panel of the
micro-boiler.
•
Please read all installa
tion
ins
tructions
completely before installing this product.
•
If you have any problems or ques
tions
regarding this equipmen
t,
consult the manufacturer or
its local representa
ti
ve.
•
These
high e
fficiency
models
have a built-in secondary heat exchanger that absorbs latent
heat from the exhaust gas.
•
The 140 Indoor (T-H3M-DV) model is only to be installed indoors. The 140 Outdoor (T-H3M-
OS) model is only to be installed outdoors.
•
The principle behind condensing micro-boiler is simple:
*This diagram illustrates condensing micro-boiler design concepts only and does not accurately
represent the micro-boiler’s physical descrip
tion.
1. Your thermostat indicates a need for heat and turns on a circulator pump.
2. Fluid enters the heater.
3. The
fl
ow sensor detects the
fluid
fl
ow.
4. The computer
initi
ates the fan motor and sends a signal to the igniter to create an
ignition
spark.
5. The gas ignites and
flames
appear within the burner chamber.
6. Fluid circulates through the heat exchanger and then gets hot.
7. Using thermistors to measure temperatures throughout the micro-boiler
,
the computer
modulates the gas and water valves to ensure proper output
fluid
temperature.
8.
Your room reaches desired temperature and the micro-boiler shuts off.
Burners
Exhaust
Secondary
heat exchanger
Primary
heat exchanger
Igniter
Gas valve
Fan motor
Flow sensor
Condensate
drain port
Gas inlet
Cold water inlet
Thermistor
Hot water outlet
Thermistor
Intake port
Exhaust
Thermistor
Water control
valve
Computer
board
Summary of Contents for HS120CON-LP