Metering Tip Selection:

The final concentration of the dispensed solution is
related to both the size of the metering tip opening
and the viscosity of the liquid being siphoned. For
water-thin products, the chart at  right can be used
as a guideline. If product is noticeably thicker than
water, consult the Measurement of Concentration
Procedure below to achieve your desired water-to-
product ratio. Because dilution can vary with water
temperature and pressure, actual dilution achieved
can only be ascertained by using the Measurement
of Concentration Procedure. The clear, undrilled tip
is provided to permit drilling to size not listed should
you need a dilution ratio that falls between standard
tip sizes.

NOTE:

 A 4 LPM eductor is grey; a 16 LPM eductor

is yellow. Refer to parts diagram if unfamiliar with
names of system components.

Measurement of Concentration:

You can determine the dispensed water-to-product
ratio for any metering tip size and product viscosity.
All that is required is to operate the primed dispenser
for a minute or so and note two things: the amount
of dispensed solution, and the amount of
concentrate used in preparation of the solution
dispensed. The water-to-product ratio is then calculated as follows:

Dilution Ratio (X:1) where X = Amount of Mixed Solution — Amount of Concentrate Drawn

Amount of Concentrate Drawn

Dilution Ratio, then, equals X parts water to one part concentrate (X:1). If  the test does not yield the desired ratio, choose
a different tip and repeat the test. Alternative methods to this test are 1) pH (using litmus paper), and 2) titration. Contact
your concentrate supplier for further information on these alternative methods and the materials required to perform
them.

AccuDose Parts Diagram:

4

2

3

1

5

1

238100

Strainer washer

2

10082835

Swivel collar

3

10082816

Swivel stem

10075950

O-ring (stem/valve connection)

4

10075925

Pipe plug

5

10080710

Button, dark grey (standard)

10080711

Button, sky blue

10080712

Button, red

10080713

Button, green

10080714

Button, light grey

10080715

Button, yellow

6

10080894

Cabinet

7

10020700

Selector valve grommet

10020900

Back up ring for grommet

Description

Part No.

Key

6

7

No Tip

.187

(3/16)

2:1

3:1

Grey

.128

(30)

2:1

3:1

Black

.098

(40)

2:1

4:1

Beige

.070

(50)

3:1

8:1

Red

.052

(55)

4:1

14:1

White

.043

(57)

5:1

20:1

Blue

.040

(60)

6:1

24:1

Tan

.035

(65)

8:1

30:1

Green

.028

(70)

12:1

45:1

Orange

.025

(72)

16:1

56:1

Brown

.023

(74)

18:1

64:1

Yellow

.020

(76)

24:1

90:1

Aqua

.018

(77)

32:1

128:1

Purple

.014

(79)

45:1

180:1

Pink

.010

(87)

128:1

350:1

Ratio (per Eductor Flow)

16 LPM

Tip Colour

APPROXIMATE DILUTIONS

AT 2.86 BAR FOR WATER-THIN PRODUCTS (1.0 CP)

Orifice

Std. Drill

Size

Number

4 LPM

Summary of Contents for AccuDose 3871GB-2

Page 1: ...et ThehosehooksuppliedwithModel3871GB 2maybeinstalledonthelongtubetoallowittoconveniently hang from dispenser when not in use 7 Replace cabinet cover Push the sides in behind the latch holes to snap the cover in place The two screws provided may be installed in the holes in the cabinet sides to prevent easy removal of cover 8 Connectwatersupplyhoseofatleast13mmIDtowaterinletswivel Minimum1 76Barpr...

Page 2: ... follows Dilution Ratio X 1 where X Amount of Mixed Solution Amount of Concentrate Drawn Amount of Concentrate Drawn DilutionRatio then equalsXpartswatertoonepartconcentrate X 1 If thetestdoesnotyieldthedesiredratio choose adifferenttipandrepeatthetest Alternativemethodstothistestare1 pH usinglitmuspaper and2 titration Contact your concentrate supplier for further information on these alternative ...

Page 3: ...0 Hose hook dark grey std 10080731 Hose hook sky blue 10080732 Hose hook red 10080733 Hosehook green 10080734 Hosehook lightgrey 10080735 Hosehook yellow Hose hook provided with Model 3871GB 2 only 16 10061100 Support 17 10080920 Selectorvalvereplacementkit e Suction stub f O ring g selector valve assembly 18 690014 Meteringtip kit 19 a 10068730 Tubing 6mm x 63 5mm b 10062550 Tubing 6mm x 600mm c ...

Page 4: ...ischarge tube inner discharge tube is installed and has flooding ring e Concentrate container empty e Replace with full container f Inlet hose barb not screwed f Tighten but do not overtighten into eductor tightly g Clogged water inlet strainer g Disconnect inlet water line and clean strainer h Selector out of position h Assure selector is in position desired 3 Excess concentrate draw a Metering t...

Reviews: