Troubleshooting Chart:

* In hard water areas, scale may form inside the discharge end of the eductor, as well as in other areas of the unit that are

exposed to water. This scale may be removed by soaking the eductor in a descaling solution (deliming solution). To remove
an eductor located in the cabinet, firmly grasp water valve and unthread eductor. Replace in same manner. Alternatively,
a scaled eductor can be cleaned (or kept from scaling) by drawing the descaling solution through the unit. Operate the
unit with the suction tube in the descaling solution. Operate the unit until solution is drawn consistently, then flush the unit
by drawing clear water through it for a minute. Replace concentrate container and put suction tube into concentrate.

1. No discharge

a. No water

a. Open water supply

b. Magnetic valve not functioning

b. Install valve parts kit

c. Excessive water pressure

c. Install regulator if water pressure

exceeds

60 PSI (flowing)

d. Eductor clogged

d. Clean* or replace

2. No concentrate draw

a. Clogged foot valve

a. Clean or replace

b. Metering tip or eductor has

b. Clean (descale)* or replace

scale build-up

c. Low water pressure

c. Minimum 20 PSI (with water running)

required to operate unit properly

d. Discharge tube(s) not in place

d. Push tube firmly onto eductor discharge

or flooding ring missing from

hose barb; be sure inner discharge tube

inner discharge tube

is installed and has flooding ring.

e. Concentrate container empty

e. Replace with full container

f. Inlet hose barb not screwed

f. Tighten, but do not overtighten

into eductor tightly

g. Clogged water inlet strainer

g. Disconnect inlet water line and clean

strainer

h. Selector out of position

h. Assure selector is in position desired

3. Excess concentrate draw

a. Metering tip not in place

a. Press correct tip firmly into barb on

eductor

b. Chemical above eductor

b. Place concentrate below the eductor

4. Failure of unit to turn off

a. Water valve parts dirty or

a. Clean* or replace with valve parts kit

defective

b. Magnet doesn't fully return

b. Make sure magnet moves freely.

c. Push button stuck

c. Remove button and clean cabinet/button

to remove any dirt lodged in slide recess

5. Excess foaming in discharge a. Air leak in pick-up tube

a. Put clamp on tube or replace tube if brittle

b. Inner discharge tube not in place

b. Install inner discharge tube

6. Water discharge from air

a. Restricted discharge hose

a. Be sure discharge tube is not immersed,

vents on eductor

kinked or elevated. Be sure there is no
liquid in the discharge tube when begin-
ning to operate dispenser

b. High water pressure

b. Install pressure regulator if flowing water

pressure exceeds 60 PSI (flowing)

Solution

Cause

Problem

10084448

Proportioning & Dispensing Equipment

Hydro Systems Europe Ltd

Unit 3, The Sterling Centre
Eastern Road
Bracknell
Berks.
RG12 2PW  ENGLAND
Tel: +44 (0)1344 488880
Fax: +44 (0)1344 488879

www.hydrosystemseurope.com

Summary of Contents for AccuDose 3871GB-2

Page 1: ...et ThehosehooksuppliedwithModel3871GB 2maybeinstalledonthelongtubetoallowittoconveniently hang from dispenser when not in use 7 Replace cabinet cover Push the sides in behind the latch holes to snap the cover in place The two screws provided may be installed in the holes in the cabinet sides to prevent easy removal of cover 8 Connectwatersupplyhoseofatleast13mmIDtowaterinletswivel Minimum1 76Barpr...

Page 2: ... follows Dilution Ratio X 1 where X Amount of Mixed Solution Amount of Concentrate Drawn Amount of Concentrate Drawn DilutionRatio then equalsXpartswatertoonepartconcentrate X 1 If thetestdoesnotyieldthedesiredratio choose adifferenttipandrepeatthetest Alternativemethodstothistestare1 pH usinglitmuspaper and2 titration Contact your concentrate supplier for further information on these alternative ...

Page 3: ...0 Hose hook dark grey std 10080731 Hose hook sky blue 10080732 Hose hook red 10080733 Hosehook green 10080734 Hosehook lightgrey 10080735 Hosehook yellow Hose hook provided with Model 3871GB 2 only 16 10061100 Support 17 10080920 Selectorvalvereplacementkit e Suction stub f O ring g selector valve assembly 18 690014 Meteringtip kit 19 a 10068730 Tubing 6mm x 63 5mm b 10062550 Tubing 6mm x 600mm c ...

Page 4: ...ischarge tube inner discharge tube is installed and has flooding ring e Concentrate container empty e Replace with full container f Inlet hose barb not screwed f Tighten but do not overtighten into eductor tightly g Clogged water inlet strainer g Disconnect inlet water line and clean strainer h Selector out of position h Assure selector is in position desired 3 Excess concentrate draw a Metering t...

Reviews: