AccuDose Select Parts Diagram List:

1

Dilution Ratio (X:1) where X = Amount of Mixed Solution — Amount of Concentrate Drawn

Amount of Concentrate Drawn

Dilution Ratio, then, equals X parts water to one part concentrate (X:1). If  the test does not yield the desired ratio,
choose a different tip and repeat the test. Alternative methods to this test are 1) pH (using litmus paper), and 2) titration.
Contact your concentrate supplier for further information on these alternative methods and the materials required to
perform them.

1 GPM

3.5 GPM

Tip Color

APPROXIMATE DILUTIONS

AT 40 PSI FOR WATER-THIN PRODUCTS (1.0 CP)

Orifice

Std. Drill

Size

Number)

Ratio (per Eductor Flow)

No Tip

.187

(3/16)

3:1

6.5:1

Grey

.128

(30)

3:1

6.5:1

Black

.098

(40)

3:1

7:1

Beige

.070

(50)

4:1

10:1

Red

.052

(55)

5:1

16:1

White

.043

(57)

7:1

20:1

Blue

.040

(60)

8:1

24:1

Tan

.035

(65)

10:1

30:1

Green

.028

(70)

16:1

45:1

Orange

.025

(72)

20:1

56:1

Brown

.023

(74)

24:1

64:1

Yellow

.020

(76)

32:1

90:1

Aqua

.018

(77)

38:1

128:1

Purple

.014

(79)

64:1

180:1

Pink

.010

(87)

128:1

350:1

1

238100

Strainer washer

2

10082835 Swivel collar (moulded)

3

10082816 Swivel stem (moulded)
10075950 O-ring (two per nipple)

4

10075925 Pipe plug

5

10080710 Button, grey (standard)
10080711 Button, sky blue
10080712 Button, red
10080713 Button, green
10080714 Button, light grey
10080715 Button, yellow

6

10080894 Cabinet

7

10020700 Selector valve grommet
10020900 Back up ring for grommet

Key

Description

Part No.

Metering Tip Selection:

The final concentration of the dispensed solution
is related to both the size of the metering tip
opening and the viscosity of the liquid being
siphoned. For water-thin products, the chart at
right can be used as a guideline. If product is
noticeably thicker than water, consult the
Measurement of Concentration Procedure below
to achieve your desired water-to-product ratio.
Because dilution can vary with water temperature
and pressure, actual dilution achieved can only
be ascertained by using the Measurement of
Concentration Procedure. The clear, undrilled
tip is provided to permit drilling to size not listed
should you need a dilution ratio that falls between
standard tip sizes.

NOTE:

 A 4 LPM eductor is grey; a 14 LPM

eductor is yellow. Refer to parts diagram if
unfamiliar with names of system components.

2

3

4

5

6

7

Summary of Contents for AccuDose 38741GB

Page 1: ...ICALLY FOR CLOGGING CLEAN IF NECESSARY 6 A short discharge tube is used with the 4 LPM eductor minimum tube length is 20cm for correct operation Longer tubes 1 2 m are used with a 14 LPM eductor Do not remove the flooding rings from inside the tubes Slide end of tube with flooding ring over eductor discharge outlet Repeat for all eductors Hooks may be installed on longertubes to allow discharge tu...

Page 2: ...her 2 10082835 Swivel collar moulded 3 10082816 Swivel stem moulded 10075950 O ring two per nipple 4 10075925 Pipe plug 5 10080710 Button grey standard 10080711 Button sky blue 10080712 Button red 10080713 Button green 10080714 Button light grey 10080715 Button yellow 6 10080894 Cabinet 7 10020700 Selector valve grommet 10020900 Back up ring for grommet Key Description PartNo MeteringTipSelection ...

Page 3: ...ook sky blue 10080732 Hose hook red 10080733 Hose hook green 10080734 Hose hook light grey 10080735 Hose hook yellow Hose hooks are for 14 LPM discharge tubes 15 10080957 Selector replacement kit e support clip f Suction stub g O ring h selector valve assembly 16 690014 Metering tip kit 17 500870 Tubing 6mm x 2 1m 18 509900 Weight 19 10076301 Footvalve viton EPDM also available order 10076302 NOT ...

Page 4: ... i Selector out of position i Ensure selector is in desired position 3 Excess concentrate draw a Metering tip not in place a Press correct tip firmly into barb on selector valve b Chemical above eductor b Place concentrate below the eductor 4 Failure of unit to turn off a Water valve parts dirty or a Clean or replace with valve parts kit defective b Magnet does not fully return b Make sure magnet ...