8
1.OO overview
(continued)
2.OO installation
2.O1 Site Survey and Installation Requirements
•
Unit is to be installed by a trained technician; all local and national water regulations are to be observed.
•
Unit must be installed indoors, in an area that does not suffer excess temperature changes, direct sunlight, frost or
precipitation of any kind.
•
The area must be free of high levels of ElectroMagnetic Interference (EMI).
•
Ensure the unit will be mounted in an accessible location, above the height of the dishwasher’s detergent inlet.
•
Installer must ensure the suitability of the wall or mounting substrate, which should be flat and perpendicular to the floor.
•
Unit location should be well lit for any maintenance, and should be free of high levels of dust particulates.
•
Scheduled maintenance should be carried out on the unit at least once per year.
•
It is a legal requirement that all water supply hose sets must be compliant with IEC 61770.
•
Ensure the chemicals being used are compatible with supplied tubing. If you are unsure, please contact a local distributor.
Safety Precautions
CAUTION!
Before an installation takes place it is advisable to complete a site survey to ensure the EvoWash can be
installed in a position that meets all the requirements below.
CAUTION!
Do not install unit in potentially explosive environment (ATEX) where flammable gas, steam, fog or dust can
form an explosive combination with air.
WARNING!
Electrical installation should be completed by a qualified electrician. All local and national electrical
regulations are to be observed.
2.1O Mechanical Installation
2.11 Installing the Vacuum Breaker
(NA only)
For shipping protection the vacuum breaker / stand-pipe
assembly is not pre-installed. The user must install the
vacuum breaker / stand-pipe assembly to the dispenser
before use.
1) While supporting the swivel connector with one hand,
push in the stem of the vacuum breaker / stand-pipe
assembly with the other hand, until firmly seated in the
push-to-fit swivel connector.
2) Rotate the vacuum breaker / stand-pipe assembly into
position and snap into the mounting bracket.
3) Route 1/4” flexible plastic tubing from the vacuum
breaker to the water inlet of the spray nozzle (as shown).
NOTE:
North America
Model Shown
1.O7 Intended Use
•
The EvoWash is intended for use in industrial applications and is not suitable for domestic use.
•
The product must only be used for dispensing washing and rinse aid chemicals for warewash applications.
•
The manufacturer waives any responsibility arising from incorrect usage or transportation.
Push stem of vacuum
breaker assembly into
manifold swivel fitting.
Swivel the vacuum breaker
up and secure. Connect the
spray nozzle inlet tubing.