Safe-T-Cover
1-800-245-6333
HCF300TDS-
2
2.
Using four (4) hexhead screws for each section, assemble both "A-B" sections thru holes
provided and set on marked concrete base (FIG 2).
3. Set "D" (roof) panel on "A-B" sections and using four (4) hexhead screws fasten thru holes
provided.
4. A. Using one (1) hexhead screw attach
Outside Corner Anchoring Brackets
to "A-B"
sections. Fasten bracket to concrete using one anchor for each bracket (FIG 1A).
B. Square the “A-B” corners. Align the “B” panels so that they form a straight line. Using
one (1) hexhead screw and one (1) hit pin for each bracket attach
Inside Anchoring
Brackets
to "B" panels and concrete (FIG 1B).
C. Insert
Inside Roof Clips
in "D" (roof) panel. Using one (1) hexhead screw in each clip
attach clip to "B" (side) panel (FIG 1C).
5. Set "C' panels and lock in place.
(Solid "C" panel to be ACCESS door).
6. Provide ground-fault interrupter device in electrical circuit according to applicable codes.
Install heater as per manufacturer's instructions and governing local and national codes.
7. For maximum protection it is suggested that the area between the bottom of the enclosure and
the concrete base be caulked with the exception of the "C" panels.
DO NOT CAULK THE
BOTTOM OF THE "C" DOOR PANELS.