background image

 INSTRUCTIONS

CLEANING THE REFLECTOR AND LAMP

Unplug the reflector and allow it to cool.

• 

Wearing gloves, carefully remove the lamp and set it aside.

• 

 Mix warm, mild soap and water and apply sparingly to the reflector’s aluminum interior with a

clean washcloth. Dry with a second washcloth. Flip reflector over to cleanse both sides.

• 

 Run a dry, soft washcloth over the lamp to remove dust particles, taking care not to leave any

skin oils/fingerprints on it (try to wear gloves whenever handling the lamp).

• 

Install the lamp back into the socket in the reflector.

TIPS

The lamp may require 10‒30 minutes cooling time before restarting.

• 

After you plug in and power on the ballast, the lamp may require several minutes to reach its full

brightness. 

• 

Be aware that in the event of a momentary power interruption, the lamp will not restart

immediately.

• 

Some variation in the color of light emitted by the lamp is not unusual, especially in the first 100

hours of operation. 

• 

Never pull the cord to unplug the reflector; pull the plug only.

Avoid scratching the lamp, subjecting it to undue pressure, or getting it wet when it is hot—these

actions may cause the lamp to break.

• 

In the event of lamp breakage, immediately unplug the reflector to prevent exposure to

ultraviolet energy, which may be harmful to eyes and skin.

• 

Keep room temperature below 95°F, with adequate air circulation provided by oscillation fans in

the growing area.

• 

Please take care to consider proximity to plants when installing your fixture. Closer proximities

will give greater intensity, but they will also reduce the effective coverage footprint.

• 

Always use a heavy-duty three-pronged grounded timer, rated for at least 15 amps.

Summary of Contents for PHBC3150

Page 1: ...INSTRUCTIONS PHBC3150 315W CERAMIC METAL HALIDE E BALLAST ...

Page 2: ...farm s TM01240 240V timer The TM01240 timer is not designed for use with electronic ballasts and using it may cause the ballast to fail The Phantom CMh ballast is designed to be used with Hydrofarm power cords ONL Using it with other power cords or modifying the power or lamp cords will void the warranty DEFINITION OF TERMS Main Voltage Rated input voltage for the ballast Watts Input power Amps In...

Page 3: ... power cord into the power source electrical outlet 120 240V only NOTE For proper break in on new lamps we recommend that you run the ballast and lamp for at least 12 straight hours after initial startup This will improve lamp life and performance MOUNTING THE BALLAST ON THE WALL 1 Find a suitable location for the ballast ou will need a space at least 9 wide ou will need to install two wall screws...

Page 4: ...ue de compra original GARANTIE LIMITÉE Hydrofarm garantit que PHBC3150 ne présente pas de défauts de matériel ni de fabrication La garantie est en vigueur 3 ans à partir de la date d achat Cette garantie ne couvre pas l utilisation incorrecte l abus ou le non respect de la notice Hydrofarm selon ses critères réparera ou remplacera PHBC3150 couvert par cette garantie s il est renvoyé au centre orig...

Page 5: ...INSTRUCTIONS PHR3150 CERAMIC METAL HALIDE REFLECTOR ...

Page 6: ...t J hook or some other means of hanging the reflector securely from the ceiling into the joist or anchor Screw a second eyehook further down the joist or in an anchor to balance hanging the reflector 5 Attach a chain rope or other sturdy material to the eyehooks we recommend Hydrofarm s Light Riser item code LULIFT 6 Secure the chain rope carabiner clips etc to the CMh 315 s integrated hangers 7 U...

Page 7: ... aware that in the event of a momentary power interruption the lamp will not restart immediately Some variation in the color of light emitted by the lamp is not unusual especially in the first 100 hours of operation Never pull the cord to unplug the reflector pull the plug only Avoid scratching the lamp subjecting it to undue pressure or getting it wet when it is hot these actions may cause the la...

Page 8: ...ptional cooling kit item code PHR3150CKT SPECIFICATIONS DIMENSIONES 45 cm L x 45 cm An x 28 cm Al PESO 3 6 kg INTERIOR Aluminio de efecto martelé con reflectividad del 95 PORTALÁMPARAS PGZX18 incorporado LÁMPARAS COMPATIBLES Halogenuro metálico y tecnología cerámica de 315W T12 38 mm únicamente para portalámparas PGZX18 LENTE Disponibles con el kit de aire condicionado opcional código del producto...

Page 9: ... el PHR3150 con el tique de compra y el embalaje originales a su centro de compra La fecha de compra se basa en su tique de compra original GARANTIE LIMITÉE Hydrofarm garantit que le PHR3150 ne présente pas de défauts de matériel ni de fabrication La garantie est en vigueur pendant cinq ans à compter de la date d achat Cette garantie ne couvre pas l utilisation incorrecte l abus ou le non respect ...