Membrane Flush
When a flush is initiated, the flush valve will operate, and the flush will last 5 minutes. The flush
can occur when a tank full condition occurs or every 24 hours, depending on the jumper
settings. The inlet valve can be open or closed and the RO pump can be on or off, depending
on the jumper settings.
Water Quality Setpoint
The water quality setpoint can be adjusted from 0-999. If set to 999, the water quality lamp will
always remain green. To set the water quality setpoint, press the Setpoint key. The display will
alternate between the setpoint and SP. Use a small screwdriver to adjust the SP adjustment to
the desired setpoint value. Press the Setpoint key to return the display to the water quality
display.
Calibration
To adjust the calibration of the water quality, measure the water with a meter calibrated to a
known standard. Using a small screwdriver, adjust the CAL adjustment to get the correct
reading on the display.