background image

HydroLynx Systems, Inc.

Model 5033-XX Solar Panel

Page 2

A102759

Receiving and Unpacking

Carefully unpack all components and compare to the packing list. Notify HydroLynx
Systems immediately concerning any discrepancy. Inspect equipment to detect any
damage that may have occurred during shipment. In the event of damage, any claim for
loss must be filed immediately with the carrier by the consignee. If the equipment was
shipped via Parcel Post or UPS, contact HydroLynx Systems for instructions.

Returns

If equipment is to be returned to the factory for any reason, call HydroLynx between
8:00 a.m. and 4:00 p.m. Pacific Time to request a Return Authorization Number (RA#).
Include with the returned equipment a description of the problem and the name, address,
and daytime phone number of the sender. Carefully pack the equipment to prevent
damage during the return shipment. Call HydroLynx for packing instructions in the case
of delicate or sensitive items. If packing facilities are not available, take the equipment to
the nearest Post Office, UPS, or other freight service and obtain assistance with
packaging. Please write the RA# on the outside of the box.

Warranty

HydroLynx Systems warrants that its products are free from defects in material and
workmanship under normal use and service for a period of one year from the date of
shipment from the factory. HydroLynx Systems' obligations under this warranty are limited
to, at HydroLynx's option: (I) replacing; or (ii) repairing; any product determined to be
defective. In no case shall HydroLynx Systems' liability exceed product's original purchase
price. This warranty does not apply to any equipment that has been repaired or altered,
except by HydroLynx Systems, or that has been subjected to misuse, negligence, or
accident. It is expressly agreed that this warranty will be in lieu of all warranties of fitness
and in lieu of the warranty of merchantability.

Address

HydroLynx Systems, Inc.
950 Riverside Pkwy., Suite 10
West Sacramento, CA 95605
Phone: (916) 374-1800
Fax: (916) 374-1877
E-mail: hydro@hydrolynx.com

Copyright © 2004 by HydroLynx Systems, Inc.

Summary of Contents for 5033-XX

Page 1: ...HydroLynx Systems Inc Model 5033 XX Solar Panel Instruction Manual Document No A102759 Document Revision Date December 2004...

Page 2: ...e items If packing facilities are not available take the equipment to the nearest Post Office UPS or other freight service and obtain assistance with packaging Please write the RA on the outside of th...

Page 3: ...on 5 1 2 Specifications 5 2 0 INSTALLATION 5 2 1 Site Selection 5 2 2 Tilt Angle 5 2 3 Installation 6 3 0 THEORY OF OPERATION 6 3 1 Solar Resource 6 3 2 Solar Panel 7 3 3 Voltage Regulator 7 3 4 Power...

Page 4: ...HydroLynx Systems Inc Model 5033 XX Solar Panel Page 4 A102759 Equipment Configuration and Parts Identification Model 5033 XX Solar Panel...

Page 5: ...scent Current 10 mA Operating Temp 20 to 50 C Storage Temp 55 to 85 C 2 0 INSTALLATION 2 1 Site Selection When considering a solar site take panel alignment and shading into account The panel must fac...

Page 6: ...mast pole or standpipe with hose clamps Thread power cable with 3 pin connector through standpipe cable port Install antenna mast onto the standpipe Align panel to face true south Tighten clamps Adjus...

Page 7: ...temperature 1 kW m 25 C which allows for comparison of solar panel power ratings The NOC tests the panel performance in actual field conditions which allow designers a better estimate of true field p...

Page 8: ...overcharged Test Fixture Switches SW1 V SW2 w oL SW3 no Volt meter is connected as shown in Figure 1 Limit Manufacture s specification 4 1 2 With Load Test Power watts Testing with a Load insures tha...

Page 9: ...ense resistor and Volt meter to make this measurement Cover solar panel completely Press Pushbutton Switch SW 3 for measurement Limit 15 mA 4 2 Maintenance Inspect the module for overall integrity Che...

Page 10: ......

Reviews: