background image

Model 5033-XX Solar Panel

HydroLynx Systems, Inc.

A102759

Page 3

TABLE OF CONTENTS

SECTION NO.

PAGE NO.

Equipment Configuration and Parts Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

1.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

1.1 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

2.0 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

2.1 Site Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.2 Tilt Angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

3.0 THEORY OF OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

3.1 Solar Resource . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.2 Solar Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.3 Voltage Regulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.4 Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

4.0 TESTING & MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

4.1

Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

4.1.1 Without Load Test - Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4.1.2 With Load Test - Power (watts) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4.1.3 Reverse Dark Current Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

5.0 DRAWINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Summary of Contents for 5033-XX

Page 1: ...HydroLynx Systems Inc Model 5033 XX Solar Panel Instruction Manual Document No A102759 Document Revision Date December 2004...

Page 2: ...e items If packing facilities are not available take the equipment to the nearest Post Office UPS or other freight service and obtain assistance with packaging Please write the RA on the outside of th...

Page 3: ...on 5 1 2 Specifications 5 2 0 INSTALLATION 5 2 1 Site Selection 5 2 2 Tilt Angle 5 2 3 Installation 6 3 0 THEORY OF OPERATION 6 3 1 Solar Resource 6 3 2 Solar Panel 7 3 3 Voltage Regulator 7 3 4 Power...

Page 4: ...HydroLynx Systems Inc Model 5033 XX Solar Panel Page 4 A102759 Equipment Configuration and Parts Identification Model 5033 XX Solar Panel...

Page 5: ...scent Current 10 mA Operating Temp 20 to 50 C Storage Temp 55 to 85 C 2 0 INSTALLATION 2 1 Site Selection When considering a solar site take panel alignment and shading into account The panel must fac...

Page 6: ...mast pole or standpipe with hose clamps Thread power cable with 3 pin connector through standpipe cable port Install antenna mast onto the standpipe Align panel to face true south Tighten clamps Adjus...

Page 7: ...temperature 1 kW m 25 C which allows for comparison of solar panel power ratings The NOC tests the panel performance in actual field conditions which allow designers a better estimate of true field p...

Page 8: ...overcharged Test Fixture Switches SW1 V SW2 w oL SW3 no Volt meter is connected as shown in Figure 1 Limit Manufacture s specification 4 1 2 With Load Test Power watts Testing with a Load insures tha...

Page 9: ...ense resistor and Volt meter to make this measurement Cover solar panel completely Press Pushbutton Switch SW 3 for measurement Limit 15 mA 4 2 Maintenance Inspect the module for overall integrity Che...

Page 10: ......

Reviews: