Figure 4 

Reverse Dark Current

4.1.3 Reverse Dark Current Test

The panel should not draw current from the battery
during periods of non-operation i.e. at night. This test
verifies low Reverse Dark Current. 

(Test Fixture Switches: SW1-A, SW2-w/oL, SW3-yes)

!

Battery and current meter are connected as shown
in Figure 4; the test fixture uses a 1 Ohm sense
resistor and Volt meter to make this measurement.

!

Cover solar panel completely.

!

Press Pushbutton Switch (SW-3) for measurement.

!

Limit: 15 mA.

4.2 Maintenance

Inspect the module for overall integrity.

Check that all connections are tight and free of corrosion.

When the panel becomes dirty use water and a soft cloth or synthetic sponge to clean the
glass surface. A mild, non-abrasive detergent can be used to remove persistent
contaminants. Avoid using brushes or abrasive cleansers.

Warning:

electrical shock can occur whenever the panel becomes wet! Wear rubber

gloves whenever cleaning the panel.

5.0 DRAWINGS

Summary of Contents for 5033-XX

Page 1: ...HydroLynx Systems Inc Model 5033 XX Solar Panel Instruction Manual Document No A102759 Document Revision Date December 2004...

Page 2: ...e items If packing facilities are not available take the equipment to the nearest Post Office UPS or other freight service and obtain assistance with packaging Please write the RA on the outside of th...

Page 3: ...on 5 1 2 Specifications 5 2 0 INSTALLATION 5 2 1 Site Selection 5 2 2 Tilt Angle 5 2 3 Installation 6 3 0 THEORY OF OPERATION 6 3 1 Solar Resource 6 3 2 Solar Panel 7 3 3 Voltage Regulator 7 3 4 Power...

Page 4: ...HydroLynx Systems Inc Model 5033 XX Solar Panel Page 4 A102759 Equipment Configuration and Parts Identification Model 5033 XX Solar Panel...

Page 5: ...scent Current 10 mA Operating Temp 20 to 50 C Storage Temp 55 to 85 C 2 0 INSTALLATION 2 1 Site Selection When considering a solar site take panel alignment and shading into account The panel must fac...

Page 6: ...mast pole or standpipe with hose clamps Thread power cable with 3 pin connector through standpipe cable port Install antenna mast onto the standpipe Align panel to face true south Tighten clamps Adjus...

Page 7: ...temperature 1 kW m 25 C which allows for comparison of solar panel power ratings The NOC tests the panel performance in actual field conditions which allow designers a better estimate of true field p...

Page 8: ...overcharged Test Fixture Switches SW1 V SW2 w oL SW3 no Volt meter is connected as shown in Figure 1 Limit Manufacture s specification 4 1 2 With Load Test Power watts Testing with a Load insures tha...

Page 9: ...ense resistor and Volt meter to make this measurement Cover solar panel completely Press Pushbutton Switch SW 3 for measurement Limit 15 mA 4 2 Maintenance Inspect the module for overall integrity Che...

Page 10: ......

Reviews: