background image

Model 50386R Receiver

HydroLynx Systems, Inc.

A102682

Page 3

TABLE OF CONTENTS

SECTION NO.

PAGE NO.

1.0 INTRODUCTION....................................................................................................... 5

1.1 General Description ....................................................................................... 5
1.2 Equipment Included........................................................................................ 5
1.3 Specifications ................................................................................................. 5

2.0 INSTALLATION......................................................................................................... 5

2.1 Site Selection ................................................................................................. 5

2.1.1 Antenna ............................................................................................ 5
2.1.2 50386R ............................................................................................ 6

2.2 Connections ................................................................................................... 6
2.3 Mounting......................................................................................................... 6

3.0 THEORY OF OPERATION ....................................................................................... 6

3.1 Power Light .................................................................................................... 6
3.2 Radio: Tone and Squelch............................................................................... 7
3.3 Input/Output ................................................................................................... 7

4.0 TESTING AND MAINTENANCE ............................................................................... 7

4.1 Testing............................................................................................................ 7

4.1.1 RF Antenna Test............................................................................... 7
4.1.2 Tone Out .......................................................................................... 7

4.2 Radio Alignment ............................................................................................. 7
4.3 Maintenance................................................................................................... 8

5.0 FORMS AND DRAWINGS ........................................................................................ 8

Summary of Contents for 50386R

Page 1: ...HydroLynx Systems Inc Model 50386R Receiver Instruction Manual Document No A102682 Document Revision Date August 2006...

Page 2: ...tems If packing facilities are not available take the equipment to the nearest Post Office UPS or other freight service and obtain assistance with packaging Please write the RA on the outside of the b...

Page 3: ...1 3 Specifications 5 2 0 INSTALLATION 5 2 1 Site Selection 5 2 1 1 Antenna 5 2 1 2 50386R 6 2 2 Connections 6 2 3 Mounting 6 3 0 THEORY OF OPERATION 6 3 1 Power Light 6 3 2 Radio Tone and Squelch 7 3...

Page 4: ...HydroLynx Systems Inc Model 50386R Receiver Page 4 A102682...

Page 5: ...tandby Current 65 mA Transmit Current Drain 2 Amps Battery 12 Vdc 12 AH Charger 120 Vac 0 2 A Antenna Input Connector s N type female lightning arrestor Audio output 800 mVpp Typical Operating tempera...

Page 6: ...rs into the Sig Out signal out section of the terminal block Attach the cable shield to the ground screw see wiring diagram Attach the battery power cable into the terminal block Connect battery power...

Page 7: ...4 1 1 RF Antenna Test The antenna is tested for reflected power as if it were a transmitter antenna Attach a wattmeter and transmitter to the antenna cable Select the proper slug for reverse power an...

Page 8: ...a low maintenance item however the battery should be tested annually and replaced whenever necessary Refer to the battery manual 5 0 FORMS AND DRAWINGS AC103421 Wiring Diagram Chassis AC106249 Assemb...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...power out G Limit within specifications Yes G No G Deviation G Inject tone as specified by the HydroLynx model or radio specification Observe deviation adjust as required G Limit within specifications...