background image

HydroLynx Systems, Inc.

Model 5351R Receiver

Page 6

A102680

2.1.2 5351R 

The 5351R must be installed as close to the antenna as possible to keep antenna cable 
line loss to a minimum. The 5351R is capable of driving its output signal long distances, up 
to 5000 feet (consult factory). For outdoor or remote installations, the 5351R must be 
housed within a weather-proof enclosure; otherwise it must be kept indoors.

2.2 Connections

All wiring connections are located on the back panel.

!

Connect the antenna cable into the N-type female connector.

!

Attach the ground screw to earth ground using a #6 stranded copper wire. The ground 
lug is provided on the ground screw.

!

Attach the receiver/decoder cable using the "lug" type connectors into the Sig Out 
(signal out) section of the terminal block. Attach the cable shield to the ground screw 
(see wiring diagram).

!

Attach the battery power cable into the terminal block. Connect battery power cable to 
the battery terminals.

CAUTION: Failure to observe battery polarity will cause extensive damage.

!

Connect the AC charger to the 5-pin connector. Plug the AC charger into a standard 
AC electrical outlet.

2.3 Mounting

The 5351R is designed for "desktop" installation. Avoid placing the console in areas where 
there is a possibility of it getting wet. For use in remote locations, place the console into a 
weather-proof enclosure.

3.0 THEORY OF OPERATION

The  5351R receives data transmissions from the remote sites. The receiver circuitry 
demodulates the Frequency Modulated (FM) radio signals into audible tones for input into 
the 5351D.

3.1 Power Light

The power light is lighted whenever power is applied to the 5351R.

Summary of Contents for 5351R

Page 1: ...HydroLynx Systems Inc Model 5351R Receiver Instruction Manual Document No A102680 Document Revision Date August 2006...

Page 2: ...tems If packing facilities are not available take the equipment to the nearest Post Office UPS or other freight service and obtain assistance with packaging Please write the RA on the outside of the b...

Page 3: ...1 3 Specifications 5 2 0 INSTALLATION 5 2 1 Site Selection 5 2 1 1 Antenna 5 2 1 2 5351R 6 2 2 Connections 6 2 3 Mounting 6 3 0 THEORY OF OPERATION 6 3 1 Power Light 6 3 2 Radio Tone and Squelch 7 3 3...

Page 4: ...HydroLynx Systems Inc Model 5351R Receiver Page 4 A102680...

Page 5: ...o manual Power Required 12 Vdc Standby Current 65 mA Battery 12 Vdc 12 AH Charger 120 Vac 0 2 A Antenna Connector N type female lightning arrestor Audio Output Level 800 mVp p Typical Operating temper...

Page 6: ...rs into the Sig Out signal out section of the terminal block Attach the cable shield to the ground screw see wiring diagram Attach the battery power cable into the terminal block Connect battery power...

Page 7: ...4 1 1 RF Antenna Test The antenna is tested for reflected power as if it were a transmitter antenna Attach a wattmeter and transmitter to the antenna cable Select the proper slug for reverse power and...

Page 8: ...a low maintenance item however the battery should be tested annually and replaced whenever necessary Refer to the battery manual 5 0 FORMS AND DRAWINGS AC103421 Wiring Diagram Chassis AC106249 Assemb...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...power out G Limit within specifications Yes G No G Deviation G Inject tone as specified by the HydroLynx model or radio specification Observe deviation adjust as required G Limit within specifications...

Reviews: