Page 34
9.5 Removal and reinstallation of
the steam cylinder
9.5.1 Removal of the steam cylinder
»
Hold the control switch in position II
to pump the rest of the water out of
the cylinder.
»
Set the control switch to position 0 to
switch off the unit.
»
Disconnect unit from power supply
»
and secure against reconnection.
»
Remove unit housing cover.
»
Check the unit again to ensure no
voltage is present.
»
Shut off the water supply.
»
Wait 10 minutes so that the possibly
hot cylinder can cool down.
»
Check the temperature by carefully
approaching it with your hand, do
not touch the cylinder if the rest heat
should be too strong.
»
Remove Super Flush solenoid hose
from cylinder bottom (if applicable).
»
Remove the steam hose from the
steam hose adapter.
If the steam hose is not to be disconnected,
the steam hose adapter with the steam hose
still attached may be detached from the
steam cylinder as shown in the next figures.
»
Remove the clip from the steam
hose adapter.
»
Pull the steam hose together with
the steam hose adapter upwards.
This will disconnect it from the steam
cylinder.
»
Push the clip onto the adapter out-
side of the unit housing.
»
Separate connector halves.