Page 35
»
Lift steam the cylinder from the cylin-
der base.
9.5.2 Cylinder cleaning / O-ring
replacement
For cleaning, mechanical removal of the
deposits is usually sufficient.
Risk of eye injuries!
The clips that fix the steam cylinder halves
have sharp edges and can jump off during
dismantling.
Eye injuries are possible.
Wear proper PPE (Personal Protection Equip-
ment)!
»
Remove the cylinder flange clamps.
»
Separate cylinder halves.
»
Remove the used O-rings between
the cylinder halves, in the base and
in the steam hose adapter.
»
Clean the cylinder inside.
»
Clean the heating element(s) by
scraping or scrubbing. A small
amount of scale hardener is harm-
less.
CAUTION
!
Summary of Contents for FlexLine FLH03
Page 1: ...FlexLine Electric Heater Steam Humidifiers ÁFLH ENKÈ FLH EN E 8881164 Manual ...
Page 45: ...Page 45 11 Declaration of Conformity ...
Page 49: ...Page 49 This page intentionally left blank ...