10
Versi-Heat / Optional Heaters
The
series heaters are supplied with a 60” cord which allows for
versatile installations and locations. BE SURE HEATER IS INSTALLED
HORIZONTALLY. The Heater can be installed on either the pressure or vacuum
side of the pump.
Versi-Heat
IMPORTANT - Heater pump must provide a minimum flow of 23 GPM through the
heater.
SENSOR BODY
SENSOR
O’RING
SPACER*
(03-0003)
CAP
The
SPACER
(HQ PT# 03-0003*)
is always
required when using this assy to assure a
leak-free seal. Note the orientation of the
SPACER
, the flat side goes against the
O’RING
,
concave side towards the
CAP
.
It is not necessary to replace the existing
SENSOR BODY
unless leaking, cracked or
damaged.
Thread sealer
is not
required when screwing the
CAP
to the
SENSOR BODY
. (
hand
tighten only
)
A thread sealer such as teflon tape
will be
required if replacing the
SENSOR BODY
.
SENSOR
not included in fitting kit. (HQ PT#: 39-0021-K.)
When replacing sensors, please keep in mind that the heater assembly will contain water
pressure even with the spa’s power off. Close available slice valves and proceed with
caution not to allow water on the surrounding electronics.
HEA
TER TUBE
Universal Sensor Fitting Kit
Part Numbers
12” Temperature Sensor (HQ PT#. 48-0202-K)
24” Temperature Sensor (HQ PT#. 48-0202A-K)
46
” Temperature Sensor (HQ PT#. 48-0202B-K)
82” Temperature Sensor (HQ PT#. 48-0202C-K)
M7 Sensor Fitting Kit (HQ PT#. 39-0021-K)
15 pcs Kit, O’ring & Spacer, M7 (HQ PT#. 48-0002)
All Sensors include PT# 39-0021-K